Alphanumeric Messaging
152 025-9034AA
1
When the device is equipped with a modem, 300-baud modems should be Bell 103 compatible;
1200-baud modems should be Bell 212 compatible.
2
The Dual Trunk is capable of either 300 or 1200 baud dialup. For general compatibility with the
outside world, 300 baud should be used. This is the default we set unless you tell us otherwise.
3
The test page facility is not used for normal paging. It is not used by way of the MultiPort or Dual
Trunk cards. It is used by way of the ZlinkW function in ZbaseW, into the maintenance port (local or
remote). Its purpose is for testing only.
Communication Parameters
Serial communications may be done by way of modem, normally using the Bell 103J
standard, or by way of direct serial connection. Standard parameters are:
300 baud
7 data bits
1 parity bit, even parity
2 stop bits (1 stop bit OK)
Full duplex
No echo
If you are using a standard terminal such as an Alphamate or iXo, they are already set up
this way standard from the factory. If necessary, these parameters can be modified for non-
standard uses; see System Configuration Files in Series 2000 Paging Terminals
Installation and Maintenance.
Video Display Terminals
A video display terminal (VDT) is most useful for receptionists, operators, or dispatchers
who require constant access to the paging system for sending messages. The alpha
messaging option can handle display messages for alpha and numeric-only pagers. VDTs
are normally connected to a port on the Multiport Serial card (702-9191), although it is
also possible to use a modem and a Dual Trunk card (702-9117) with the Dual
Alphanumeric Messaging input modem option (950-9108). The descriptions given below
are for the Multiport Serial card, with differences noted for the Dual Trunk card where
appropriate.
Note If communicating by way of modem, it is very important that line
levels and balance be properly adjusted; refer to the Installation
manual for adjustments.