Trunk Cards and Connections
78 025-9035AA
noise/static between words and when talker obviously paused) then turn the pot
counterclockwise.
Factory adjustment for From Tel
1. Attach a voltmeter to the FROM TEL and GND test points on the front of the trunk
card. For dual trunks, be sure to attach to the A or B test points for the correct side
of the dual trunk. Set the meter to measure AC volts RMS.
2. Have an assistant call into the paging system using a touch tone telephone. Call
any tone and voice pager programmed in the database. It should have a long voice
time so you have time to make the adjustment. Make sure you have called into the
line you are adjusting. Call in on the real telephone line - do not just stick a butt set
across the line.
3. Hold down one of the touch tone keys on the telephone.
4. Set the level appropriate for your revision of card, as follows:
Please note that you are positioning the knee of the AGC circuit for optimum operation.
Hybrid Adjustment
BAL R and BAL C adjust the full duplex hybrid balance for the particular telephone line.
Some adjustment is often required to compensate for the particular telephone line and
routing to the telco office.
If you swap telephone lines around, or the telco changes your lines, you should perform
this adjustment again.
The hybrid isolates what the Zetron trunk card puts onto the telco line from what it
receives from the telco line, separating the two paths: inward and outward.
Trunks Covered Settings
Single Trunks & Dual
Trunks revs. A-C
Set the meter range for 1 to 2 Vac
Adjust FROM TEL for 0.75 Vrms +/- 0.25 V (0dBm)
If you are using the trunk for alpha communications via a dialup
modem, use a slightly higher level of 1.0 Vrms ±0.25 V for more
reliable modem connections.
Dual Trunks
revs. D & E
Do not adjust. Factory adjustment only.
If you change the level in error, put it back to the approximate factory
setting by: turning it all the way counter-clockwise until it clicks,
then turning it six full turns clockwise.
Dual Trunks
revs. F & up
Install the shunt jumper (see page 81) in the KILL A or KILL B
position while adjusting. Do not install the KILL jumper until
ready to adjust, as DTMF decoding will probably not work with
the jumper in.
Set the meter range for 3 to 5 Vac. Adjust FROM TEL for
2.5 Vrms ±0.25 V (12dBm).
Remove KILL jumper.