116 025-9035AA
If an SSC is not working, check that its CPA line jumper is set for
CPA to CPA, not CPA to CPB.
Motorola ASC (Advanced Simulcast Controller)
Figure 24: Interfacing to Motorola Advanced Simulcast Controller
* If the ASC has an internal modem option, you would not use the 202T, and would
cross-wire MODEM TIP to AUDIO TIP, and MODEM RING to AUDIO RING.
** At the time we tested with the ASC, it would not accept direct binary data input,
so required the external modem. We show both methods here.
Refer to the ASC Service Manual and Installation Guide for the P2 connector pinout.
Please note that the zoning (Sector Select on ASC) is an option on the ASC. The
parameter settings are the same as for the PSC/SSC/DDC on the previous page, but
parameter 06 (digital data polarity) may need to be inverted.
ANA PTT NO 31
DIG PTT NO 33
COR/CAS 4
BUSY 29
XMIT AUDIO HI 3
XMIT AUDIO LO 28
ZONE ADR 8 9
ZONE ADR 4 34
ZONE ADR 2 10
ZONE ADR 1 35
**DIG DATA 30
— or
**DIG DATA 30
ANA PTT COM 6
DIG PTT COM 8
GROUND 5
42 KA Key Analog
43 KD Key Digital
17 CPA
(Clear to Page Analog)
18 CPB
(Clear to Page Binary)
47 AUDIO TIP
22 AUDIO RING
13 Sector Select 3
38 Sector Select 2
12 Sector Select 1
37 Sector Select 0
48 MODEM TIP*
23 MODEM RING*
— or
26 BINARY DATA
19 SIGNAL GROUND
16 SIGNAL GROUND
31 SIGNAL GROUND
Zetron 2000 Series
Paging Terminal
2100 Slot 9
2200 Slot 15 or 13
Signal Pin#
TX TIP
RTS Ring
+12V
UDS 202T Modem
Motorola
ASC Controller
P2
Connector
Pin# Signal